VENTING SPECIFICATIONS FOR
INSTALLATION

The fireplace chimney flue and vent must be
drafting.properly..To.check.the.vent.for.proper.
drafting: Light a tightly rolled newspaper on
one.end.and.place.it.at.the.inside.front.edge.
of the fireplace. Observe the smoke and be
sure the vent is properly drawing it up the
chimney. If the smoke spills out into the room,
extinguish the flame and remove any obstruc-
tion.until.proper.venting.is.achieved.
The chimney flue must remain open a mini-
mum of 3" at all times during the operation of
this.log.set.

MODEL

BURNER

DESCRIPTION

BTU

INPUT

MINIMUM VENT

OPENING

VTD-18N-JHB

18" Ramp

59,000

8" dia.

VTD-24N-JHB

24" Ramp

69,000

8" dia.

VTD-30N-JHB

30" Ramp

74,000

8" dia.

INSTALLATION

Continued

MINIMUM FIREBOX SIZES

MODEL

FRONT WIDTH

BACK WIDTH*

DEPTH

HEIGHT

VTD-18N-JHB

28"

16"

14"

18"

VTD-24N-JHB

9.

3

/

4

"

17"

15.

1

/

"

18"

VTD-30N-JHB

36"

27"

18"

18"

*At.depth.indicated

BURNER ORIFICE

LOG SIZE

NATURAL

INCHES

NUMBER

18"

0.1495

5

24"

0.1570

30"

0.1660

19

FUEL INLET PRESSURE

SPECIFICATIONS (W.C.)

MIN.

MAX.

NG

5.5"

10.5"

Figure 2 - Technical Information Charts

INSTALLING DAMPER CLAMP

Secure.the.damper.stop.clamp.to.the.edge.of.
the damper as shown in Figure 3. If for any
reason this clamp doesn't work on your fire-
place, another suitable clamp or permanent
stop must be installed, or the damper blade
must.be.cut.or.removed.