VENTING SPECIFICATIONS FOR
INSTALLATION
The fireplace chimney flue and vent must be
drafting.properly..To.check.the.vent.for.proper.
drafting: Light a tightly rolled newspaper on
one.end.and.place.it.at.the.inside.front.edge.
of the fireplace. Observe the smoke and be
sure the vent is properly drawing it up the
chimney. If the smoke spills out into the room,
extinguish the flame and remove any obstruc-
tion.until.proper.venting.is.achieved.
The chimney flue must remain open a mini-
mum of 3" at all times during the operation of
this.log.set.
MODEL
BURNER
DESCRIPTION
BTU
INPUT
MINIMUM VENT
OPENING
VTD-18N-JHB
18" Ramp
59,000
8" dia.
VTD-24N-JHB
24" Ramp
69,000
8" dia.
VTD-30N-JHB
30" Ramp
74,000
8" dia.
INSTALLATION
Continued
MINIMUM FIREBOX SIZES
MODEL
FRONT WIDTH
BACK WIDTH*
DEPTH
HEIGHT
VTD-18N-JHB
28"
16"
14"
18"
VTD-24N-JHB
9.
3
/
4
"
17"
15.
1
/
"
18"
VTD-30N-JHB
36"
27"
18"
18"
*At.depth.indicated
BURNER ORIFICE
LOG SIZE
NATURAL
INCHES
NUMBER
18"
0.1495
5
24"
0.1570
30"
0.1660
19
FUEL INLET PRESSURE
SPECIFICATIONS (W.C.)
MIN.
MAX.
NG
5.5"
10.5"
Figure 2 - Technical Information Charts
INSTALLING DAMPER CLAMP
Secure.the.damper.stop.clamp.to.the.edge.of.
the damper as shown in Figure 3. If for any
reason this clamp doesn't work on your fire-
place, another suitable clamp or permanent
stop must be installed, or the damper blade
must.be.cut.or.removed.