Mechanical & electrical installation, Mechanical installation, Electrical installation – Daktronics GM-2101 LED Gymnastics Scoreboards User Manual
Page 13: Power, Signal, Section 3

Reference Drawings:
Mechanical Spec, GM-2101-13 .............................................................. Drawing A-247202
Mechanical Spec, GM-2102-13 .............................................................. Drawing A-247272
Mechanical Spec, GM-2103-13 .............................................................. Drawing A-247301
All Daktronics gymnastics scoreboards may be displayed on the floor on a table, or mounted
on an optional tripod. Use only the tripod (part number A-1580) and adapter (HS-1306)
supplied by Daktronics. Drawings A-247202, A-247272, and A-247301 in Appendix A show
how to mount the display on a tripod. Locate the holes on the bottom of the scoreboard and
secure the display to the tripod adaptor using the hardware provided.
The single-sided gymnastics display (GM-2101) may also be wall mounted (the two- and
three-sided scoreboards in this manual cannot). Refer to Drawing A-220834 for mounting
keyhole locations on the back of the display. Due to the variety of wall materials used in
sports facilities, Daktronics cannot anticipate a user‟s needs or provide mounting hardware
suitable for every installation. Mounting hardware may be purchased at a local hardware
store. Choose a method of installation that will safely support the weight of the display.
Note: Do not use the carrying handle to permanently suspend the display.
Reference Drawings:
Electrical & Signal Spec, GM-2101-13 ................................................... Drawing A-247207
Electrical & Signal Spec, GM-2102-13 ................................................... Drawing A-247278
Electrical & Signal Spec, GM-2103-13 ................................................... Drawing A-247309
Electrical installation involves the routing of power and control signal wiring to the displays.
Control signal cable is not provided as part of this system; it can be purchased locally or from
Daktronics. Refer to Drawings A-247207, A-247278, and A-247309 in Appendix A for
detailed power and signal connection diagrams for each gymnastics scoreboard model.
Each display comes equipped with a 120V AC, three-prong plug. Install a grounded
receptacle near the equipment and make certain that the power cord can easily reach it.
The control console requires a 120 V AC receptacle and uses less than 1 A of power.
Displays operating on 230 V AC are also available, and they are shipped equipped with a
universal power plug.
1. Route the signal cable from the display to the control location.
2. Plug the signal cable into the J31 SIGNAL IN jack on the side of the display.
3. Plug the other end of the signal into the J1 or J2 jack on the All Sport 1600 controller.