Maintenance & Troubleshooting

5

Section 3:

Maintenance & Troubleshooting

IMPORTANT NOTES:

1. Always disconnect power before doing any repair/maintenance work on the display.

2. Permit only qualified service personnel to access internal display electronics.

3.

Disconnect power when not using the display.

3.1 Display Information

Daktronics backlit scorer‟s tables occasionally require replacement of failed lamps or ballasts.
Refer to Drawings B-381209 and B-381575 in Appendix A for detailed wiring schematics and
refer to Section 3.6 for replacement part numbers.

Do not use higher power lamps or damage to the circuit may result.

Obtain replacement lamps and ballasts from Daktronics or a local store.

3.2 Display Access

1. Lift an end pad off one side of

the scorer‟s table and set aside.

2. Carefully slide the face panel out

of the retainer frame to expose
the internal components.


Refer to Figure 5.

Note: When multiple tables are
linked together, the metal latches
must be disconnected and the tables
separated before the face panel can
be removed.

3.3 Lamp Replacement

Lamps are held by “tombstone “-style fluorescent lamp sockets on each end. One socket for
each lamp will be spring-loaded.

1. Access the display components as described in Section 3.2.
2. To replace a lamp, grasp and push the lamp towards the spring-loaded end of the lamp

holder, then pull it out.

3. Replace lamps per the replacement parts list (refer to Section 3.6). Lamp sizes are given

in inches, stamped on one end of the bulb. The size is indicated by the set of numbers
following the letter “F.”

4. Close the display and reconnect power.

Figure 5: Front Display Access