3.5 VENTING APPLICATION FLOW CHART

13.1

TOP EXIT

Horizontal Termination

Vertical Termination

Vertical rise is equal

to or greater than

the horizontal run

Vertical rise is less

than horizontal run

Vertical rise is equal

to or greater than

the horizontal run

Vertical rise is less

than horizontal run

Horizontal run +

vertical rise to

maximum of 40 feet

Horizontal run +

vertical rise to

maximum of 24.75

feet

Horizontal run +

vertical rise to

maximum of 40 feet

Horizontal run +

vertical rise to

maximum of 40 feet

4.2 times the

vertical rise equal to

or greater than the

horizontal run

3 times the vertical

rise equal to or

greater than the

horizontal run

13.2

REAR EXIT

Horizontal Termination

Vertical Termination

Vertical rise is equal

to or greater than

the horizontal run

Vertical rise is less

than horizontal run

Vertical rise is equal

to or greater than

the horizontal run

Vertical rise is less

than horizontal run

Horizontal run +

vertical rise to

maximum of 40 feet

Horizontal run +

vertical rise to

maximum of 24.75

feet

Horizontal run +

vertical rise to

maximum of 40 feet

Horizontal run +

vertical rise to

maximum of 40 feet

3.5 times the

vertical rise equal to

or greater than the

horizontal run

3 times the vertical

rise equal to or

greater than the

horizontal run