Electrical Safety

The LNA Low Noise Amplifier Series has been shown to comply with the following safety
standard:


• EN 60950: Safety of Information Technology Equipment, including electrical

business machines

The equipment is rated for operation over the range 100 - 240 volts AC. It has a maximum power
consumption of 60 watts, and draws a maximum of 600 mA.


IMPORTANT


The user should observe the following instructions:

Fuses

The LNA is fitted with two fuses - one each for line and neutral connections. These are contained
within the body of the IEC power inlet connector, behind a small plastic flap.

• For 115 and 230 volt AC operation, use T1.25A, 20mm fuses.


FOR CONTINUED OPERATOR SAFETY, ALWAYS REPLACE THE FUSES WITH
THE CORRECT TYPE AND RATING.

Environmental

The LNA must not be operated in an environment where the unit is exposed to extremes of
temperature outside the ambient range 0 to 50°C (32° to 122°F), precipitation, condensation, or
humid atmospheres above 95% RH, altitudes (un-pressurized) greater than 2000 metres,
excessive dust or vibration, flammable gases, corrosive or explosive atmospheres.

Operation in vehicles or other transportable installations that are equipped to provide a stable
environment is permitted. If such vehicles do not provide a stable environment, safety of the
equipment to EN60950 may not be guaranteed.

Installation

The installation and connection to the line supply must be made in compliance to local or national
wiring codes and regulations.