Major assembly, Installation – Comtech EF Data CMR-5930 Quick Start Guide User Manual

Page 2

background image

Major Assembly

The Comtech EF Data CMR-5930 Digicast PID Filter ASI is available in a standalone configuration. The
following table lists the components provided with a standard configuration. In the event any listed item is
missing, please contact Comtech EF Data Customer Support.

CMR-5930 Digicast PID Filter ASI – Standalone Configuration

Quantity Description

1

CMR-5930 Digicast PID Filter ASI

1

SPU24-102 Power Supply

1 IEC

Power

Cable

1

CA-TERMINAL Terminal Cable

1 CD

(includes Quick Start reference and Installation and Operation Manual)

1

Quick Start sheet

Installation

The CMR-5930 is designed for ease of installation and configuration. Once the unit has been removed from the
packing container, follow these instructions:

Step

Procedure

1

Place the CMR-5930 on a flat surface with free-air flow where the LEDs can be clearly observed with
unrestricted access to the rear panel of the unit.

2

Connect the DC power connection to the connection labeled PWR on the back of the unit and tighten the
restraining nut to ensure secure operation.

3

Connect an RJ-45 Ethernet cable (patch cord) to the port labeled ETHERNET. This cable should be connected
to an Ethernet concentrator (hub) or switch.

4

Connect a terminal cable (supplied) to the port labeled TERM. This cable should be connected to a PC’s serial
port (DB-9) to initially configure the CMR-5930.

5

Connect the AC power cord between a standard wall outlet and the power supply. The Blue LED will illuminate.

6

IMPORTANT

It is recommend that the ASI cable NOT be connected until the unit has been
completely configured.

7

Upon startup, the LEDs on the CMR-5930 front panel become operational as follows:

LED

Function Label

Description

Blue

PWR

LED illuminates if power is properly applied

Red

ALARM

LED may illuminate since the unit is not yet configured

Green

SYNC

LED illuminates if the ASI in SYNC is detected

Green

RED

LED will not illuminate – reserved for future redundancy functionality

Amber

E-COL

LED flashes if there are collisions on the Ethernet switch

Green

E-RX

LED flashes if there is activity on the switch

Green

E-TX

LED flashes if the unit is transmitting data to the Ethernet

Green

E-LINK

LED illuminates if the Ethernet connection to the Hub/Switch is
operational