background image

RRS11 Solid-State Transfer Switch

Operation

MN-RRS11

3–5

Rev. 3

An additional 9-Pin D-Sub Connector is supplied for switch monitoring. The I/O on this connector
comes from a Form-C relay. The pinouts for the monitor connector is listed in Table 3-3.

Table 3-3. Switch Online Statue Pinout

Pin No.

Signal Name

Description

4

Signal Ground

Switch GND

1

Relay 1 NO

Relay Normally Open Contact

(Closed When the Backup Modulator is On-Line)

3

Relay 1 NC

Relay Normally Closed Contact

(Closed When the Prime Modulator is Online)

2

Relay 1 C

Relay Common Contact

7

Relay 2 NO

Relay Normally Open Contact

9

Relay 2 NC

Relay Normally Closed Contact

8

Relay 2 C

Relay Common Contact

5

NC

---

6

NC

---