beautypg.com

1 litres, 20 user’s manual, Troubleshooting, maintenance, recycling 3 – Dometic TEC 40D User Manual

Page 22: 3 extraordinary maintenance, Changing the oil

background image

TEC 40D

20

user’s manual

GB

Troubleshooting, maintenance, recycling 3

Important

Old oil moust not be disposed of in the environment, but left

to a station specialised in the disposal and/or recycling of the

same, respecting the laws in the country where the operations

are carried out.

Use oil recommended for 4-stroke Diesel engines of these types:

CCMC-D4-D5-PD2 or API-CD-CE-CF-CG or SHPD (this indication is
on the oil can).

SAE 10W-30 oil is recommended for general use at all temperatures.

If you use monograde oil, choose the appropriate viscosity on the

basis of the average temperature of the place where the generator is

installed.

To drain the old oil easier you should run the generator for roughly 3/5

minutes, in this way the oil is more fluid and will drain better through the

drain tube when you remove the drain plug. Refill the generator with oil

of the recommended type, through the oil filler.

The quantity of oil is:

3.3 Extraordinary maintenance

For some maintenance operations there is the possibility of pulling

the generator out by sliding the entire bottom of the generator on

the guides fixed to the sidewalls of the casing. To set the gene-

rator basis free loosen the harness and unscrew the 4 fastening

screws. The generator unit will be extractable by ¾ of its depth.

To come to a complete extraction put the generator basis on firm

ground to protect it against possible falls and unscrew the 2 limit

stop screws. Alternatively tighten the generator basis inserting

screws in inner position.

Changing the oil

Warning

Hot oil can burn your skin!

Check the oil level with the engine turned off.

122

104

86

68

50

32

14

-4

-22

-40

50

40

30

20

10

0

-10

-20

-30

-40

°F

°C

5W/30

5W/40

10W

10W/30

10W/40

15W/40

20W/20

30

40

OIL : SAE

Oil drain plug

1.1 Litres