Mounting and alignment of fixture, Electrical connection (hardwire) – Coloronix Adjustable 15-LED RGBW Flood Light User Manual
Page 9

Page 9 of 13 - Coloronix SS2 Direct Power Lighting Manual V.2.0.1
Mounting and Alignment of Fixture
Mounting and Alignment of Fixture
Mounting and Alignment of Fixture
Mounting and Alignment of Fixture
•
Mount and secure each fixture into the designated position in accordance to the
installation plan. Ensure there is sufficient cable length between the fixture and junction
box to allow for final alignment of the fixture.
•
Secure the fixtures to a solid mounting surface using three threaded fasteners
minimum of 3/8 inch (10mm) stainless steel complete with flat and locking washer.
•
Rotate the fixtures using the pan and tilt method into the desired position.
Electrical Connection (Hardwire)
WARNING: Do not expose bare wires outside wire nut connectors.
1. Per local or “National Electric Code”, provide electrical service to junction box
located on the housing.
a. The insulation of supply wire must be rated for at least 90°C.
b. Junction boxes should be rated for:
i. Max. 8 No. 12 AWG Circuit Conductors
ii. Also suitable for at least 90°C
2. Remove cover of junction box.
3. Remove proper round pryout, and then connect junction box with (not included)
proper connector.
4. Using properly sized wire nuts, connect lead wires of junction box (line, neutral,
and ground) to supply lead wires in the fixture.
a. WARNING: Do not leave bare conductors outside wire nut connectors.
5. Connect green (from electrical service) to the supply side to the green wire in
the junction box. Connect black-to-brown, and white-to-blue.
a. Any excess wiring and connectors should be put in the junction box.
Then, replace the cover.
NOTE: Supply lead wires should not be connected to a dimmer of any sort.
Maximum power connection should not exceed 9 units at 120V.