beautypg.com

Maintenance – Coloronix Adjustable 15-LED RGBW Flood Light User Manual

Page 11

background image

Page 11 of 13 - Coloronix SS2 Direct Power Lighting Manual V.2.0.1

Maintenance

Maintenance

Maintenance

Maintenance

Coloronix recommends periodic cleaning of the heat sink and lens. Over time these
components can b

ecome dirty or full of debris. This can result in lack of cooling or can

limit the capabilities of the fixture.

Lens Maintenance

Clean the front Lexan® as required using any of the following cleaners:

• Window Cleaner
• Mild soap and water solution

In addition, dry the Lexan® with a quality paper towel to avoid scratches or streaks.

Mount/Fasteners Maintenance

Check all fasteners annually for tightness and security to avoid damage to the fixture
and possibly liability.

Troubleshooting

If problems occur during usage, unplug the product immediately and call or email:

Coloronix, Inc.
Tech Support: (909) RGBW-555

[email protected]

Replacing a Failed Fixture


“Hot Swapping” a fixture is not allowed. If a fixture needs to be replaced, the steps are
to:

1. Disconnect the DMX input at the junction box of the fixture needing

replacement.

2. Disconnect DMX output.
3. Replace fixture.
4. Reconnect AC negative.
5. Reconnect AC positive.
6. Reconnect DATA output.
7. Reconnect DATA input.
8. Reconnect power.

Make sure the replaced fixture and the entire system is in working order.