beautypg.com

Cb 9 series – Code Blue CB 9-S SIGNATURE SHORT ENCLOSURE User Manual

Page 30

background image

Code Blue

259 Hedcor Street

Holland, MI 49423 USA

800.205.7186

www.codeblue.com

GU-159-D

page 30 of 38

CB 9 Series

Administrator Guide

20 CB 9 Series Deck Mount Installation Instructions

1.0 DECK MOUNT FOUNDATION

1.1 Drill Deck Holes – Drill four holes through the deck or floor for the four 3/4” threaded rods.

The holes should be aligned, using the template provided in such a way that the phone face-

plate on the unit will face in the desired direction (see figure below).

1.2 Drill a fifth hole in the center to accommodate the conduit.
1.3 Position Upper Deck Plate – Position the first plate working from above the deck.

1.3.1 Thread a nut and washer on the end of each rod so that approximately six inches ex-

tends beyond the base of the washer.

1.3.2 Insert each rod through the top side of the plate, plate gasket, and down through the

four holes in the deck.

NOTE: The top of the plate is the side with the tapered edge.

1.4 Position Lower Deck Plate – Position the second plate working from below the deck. Have

another worker hold the upper plate and rods in place from above the deck.
1.4.1 Place the second plate gasket and then the second plate over the threaded rods.
1.4.2 Secure the second plate with nuts and washers provided. If required, readjust the nuts

so that six inches of the rods are above the top of the upper plate (see figure below).

1.5 Secure Lower Nuts – To prevent tampering, it is advisable to tack weld the lower nuts to the

threaded rod.

2.0 WIRING

2.1 Pull power and phone line through conduits – A minimum of two feet of wire must be avail-

able from the conduit for electrical and communications wiring.

2.2 Conduit – Electrical and telephone line conduit is run through the deck and the center open-

ings (two-inch diameter) of the upper and lower deck plates. A minimum of four inches and a

maximum of six inches of conduit above the upper plate is required.

B

B

CB 1 Base

3/4" THREADED ROD OF SUFFICENT

LENGTH TO PASS THROUGH DECK

AND ALLOW A MINIMUM OF 6”

ABOVE THE TOP DECK PLATE.

6.00

Ø14.00
DECK PLATE

PHONE

FACEPLATE

DIRECTION

ALLOW

1/2" GAP FOR

VENTING

ELECTRICAL

AND TELEPHONE

LINE CONDUIT

Ø8.00
BOLT CIRCLE