20 CB 9 Series Deck Mount Installation Instructions
1.0 DECK MOUNT FOUNDATION
1.1 Drill Deck Holes – Drill four holes through the deck or floor for the four 3/4” threaded rods.
The holes should be aligned, using the template provided in such a way that the phone face-
plate on the unit will face in the desired direction (see figure below).
1.2 Drill a fifth hole in the center to accommodate the conduit.
1.3 Position Upper Deck Plate – Position the first plate working from above the deck.
1.3.1 Thread a nut and washer on the end of each rod so that approximately six inches ex-
tends beyond the base of the washer.
1.3.2 Insert each rod through the top side of the plate, plate gasket, and down through the
four holes in the deck.
NOTE: The top of the plate is the side with the tapered edge.
1.4 Position Lower Deck Plate – Position the second plate working from below the deck. Have
another worker hold the upper plate and rods in place from above the deck.
1.4.1 Place the second plate gasket and then the second plate over the threaded rods.
1.4.2 Secure the second plate with nuts and washers provided. If required, readjust the nuts
so that six inches of the rods are above the top of the upper plate (see figure below).
1.5 Secure Lower Nuts – To prevent tampering, it is advisable to tack weld the lower nuts to the
threaded rod.
2.0 WIRING
2.1 Pull power and phone line through conduits – A minimum of two feet of wire must be avail-
able from the conduit for electrical and communications wiring.
2.2 Conduit – Electrical and telephone line conduit is run through the deck and the center open-
ings (two-inch diameter) of the upper and lower deck plates. A minimum of four inches and a
maximum of six inches of conduit above the upper plate is required.
B
B
CB 1 Base
3/4" THREADED ROD OF SUFFICENT
LENGTH TO PASS THROUGH DECK
AND ALLOW A MINIMUM OF 6”
ABOVE THE TOP DECK PLATE.
6.00
Ø14.00
DECK PLATE
PHONE
FACEPLATE
DIRECTION
ALLOW
1/2" GAP FOR
VENTING
ELECTRICAL
AND TELEPHONE
LINE CONDUIT
Ø8.00
BOLT CIRCLE