1.0 PRE-INSTALLATION
1.1
Electrical preparation – The unit may have supply wires run from either (a) behind the unit
through the wall, or (b) below the unit using an external conduit through the bottom of the unit.
Holes in the back and bottom of the unit have been provided for this purpose.
2.0 INSTALLATION PROCEDURES
2.1 Remove the top of the unit.
2.2
Mark the mounting holes – In order to comply with the Americans with Disabilities Act (ADA)
of 1990, the speakerphone button(s) should be positioned between 34 and 48 inches from
grade level. (Consult an ADA specialist in your area to verify local and federal guidelines.)
2.3 Drill all marked holes.
2.4
Install the housing – Four anchors of appropriate size and type should be used to fasten the
housing to the wall.
IMPORTANT: If wiring is supplied from the back, ensure that the conduit is aligned at this time.
2.5 Reattach the top.
3.0 ELECTRICAL WIRING
3.1
Ground – The ground (green) wire should be stripped and fastened to the supplied grounding
lug.
3.2
24V AC supply – Using the proper crimping tool, attach a #8 fork to each of the incoming
power wires and fasten them to the terminal screws labeled “Line” and “Neutral.”
3.3
120/240V AC supply – Using the proper crimping tool, attach a #8 fork to each of the incom-
ing power wires and fasten them to the correct terminals as labeled on the transformer. After
completing the wire connections install the supplied terminal covers.
4.0 COMMUNICATIONS WIRING
4.1 Have category 3 or higher 4-pair cable terminated to a RJ45 applying TIA/EIA T568-B speci-
fications.
See diagrams next page