10 cm – Code CR5000 User Manual
Page 6
6
D021992_02 CR5000 User Manual
6.0 - Reading Ranges
4.0 - Using a CR5000
in Presentation Mode
5.0 - Using a CR5000
in Handheld Mode
Note: Handheld working ranges are a combination of both the wide and high density fields. All samples were high quality barcodes and were read
along a physical center line at a 10° angle. Default AGC settings were used. Accuracy= +/- 10%.
CR5000 Performance
Presentation Mode (Default)
Handheld Mode
Test Barcode
Min Inches (mm)
Max Inches (mm)
Min Inches (mm)
Max Inches (mm)
5.8mil PDF
0” (0 mm)
2.0” (50 mm)
0.4” (10 mm)
4” (100 mm)
6.3mil DM
0” (0 mm)
2.4” (60 mm)
0.4” (10 mm)
4.5” (115 mm)
6.6mil PDF
0.4” (10 mm)
2.6” (65 mm)
0.4” (10 mm)
4.5” (115 mm)
10mil DM
0.4” (10 mm)
3.5” (90 mm)
0.4” (10 mm)
5.5” (140 mm)
13mil UPC
0.4” (10 mm)
4.9” (125 mm)
0.4” (10 mm)
7.5” (190 mm)
15 mil DM
0.4” (10 mm)
4.5” (115 mm)
0.4” (10 mm)
6.9” (175 mm)
20mil DM
0.4” (10 mm)
6.1” (155 mm)
0.4” (10 mm)
8.0” (205 mm)
10 cm
J NR
M
NR
PM
QR
-15°
0°
15°
30°
45°