P25 RADIO SYSTEMS | TRAINING GUIDE
Chapter 5: Conventional Fixed Station Interface Page 67
Function Tones used for additional control of the fi xed station are shown in Table 5-1:
Tone Function
Secondary
Function
2050 Hz
Monitor Receiver
1950 Hz
Transmit Channel 1
1850 Hz
Transmit Channel 2
1350 Hz
Transmit Channel 3
Select Digital mode
1250 Hz
Transmit Channel 4
Select Analog mode
1150 Hz
Transmit Channel 5
Select Secure mode
1050 Hz
Transmit Channel 6
Select Clear mode
1750 Hz
Transmit Channel 7
Second receiver off
1650 Hz
Transmit Channel 8
Second receiver on
1550 Hz
Repeater mode off
1450 Hz
Repeater mode on
Table 5-1: Tone Remote Control Function Tones
Although secondary functions can be used to select Analog / Digital and Secure / Clear modes, these