Common Mode Rejection
-65dB / 10kHz
Crosstalk
-70dB / 10kHz
Gain Range
+6dB / -12dB
Sub-sonic Filter
-3dB 20Hz 18dB/oct Butterworth
Crossover Filters
18dB/oct Butterworth
Nominal output level
0dBu balanced / -6dBu unbalanced
Minimum load impedance
600Ω
Maximium output level
+26dBu balanced / +20dBu unbalanced
Power consumption
7.5 VA
Power requirements
230V ± 10% / 115V ±10% 40-60Hz AC
Fuse ratings
230V – T50mA 115V - T100mA
Dimensions
Width 482.6mm (19" rack mtg)
Height 44.0mm (1U) Depth 175.0mm
Weight
3Kgs
This product conforms to the following European Standards
EN 50081-1: 1992
EN 50082-1: 1992
EN 60065 : 1994
SAFETY CONSIDERATIONS
CAUTION - MAINS FUSE
TO REDUCE THE RISK OF FIRE REPLACE THE MAINS FUSE ONLY WITH THE SAME
TYPE, WHICH MUST BE A CLASS 3, 240 VOLT, TIME DELAY TYPE, RATED AT 50mA
WHERE THE MAINS INPUT VOLTAGE IS SET TO 230 Volts ± 5% AC. FOR A MAINS
VOLTAGE OF 115 Volts ± 5% AC. THE FUSE SHOULD BE RATED AT 100mA
THE FUSE BODY SIZE IS 20mm x 5mm.
CAUTION - SERVICING
THIS UNIT CONTAINS NO USER SERVICEABLE PARTS. REFER ALL SERVICING TO
QUALIFIED SERVICE PERSONNEL. DO NOT PERFORM ANY SERVICING UNLESS YOU
ARE QUALIFIED TO DO SO.
WARNING
TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK DO NOT EXPOSE THIS
EQUIPMENT TO RAIN OR MOISTURE.
22/12/00