Bs en 55103-1:1997, Bs en 55103-2:1997, Bs en 60065:1998 – Cloud Electronics CX242 User Manual
Page 12: Safety considerations and information, Caution – servicing, Caution – installation, Caution - mains fuse, 12 general specifications
![background image](https://www.manualsdir.com/files/778459/content/doc012.png)
CX242: I
NSTALLATION AND OPERATION MANUAL
11
15/07/02 V4
12 General
Specifications
Remote music mute attenuation
Adjustable -20dB to -70dB
Remote music mute connection
2 core cable to isolated relay contacts
Line 4 priority release time
Adjustable 3, 6 or 12 seconds
Power consumption
15VA
Power requirements
230V±10% or 115V±10%
T100mA H for 230V input
Fuse rating
T200mA H for 115V input
Fuse type
20mm x 5mm class 3 T 250V
Width 482.60mm
Height 44mm
Depth 160mm
Weight
3.50kg including packing
This product conforms to the following European EMC Standards:
BS EN 55103-1:1997
BS EN 55103-2:1997
This product has been tested for use in commercial and light industrial environments. If the equipment
is used in controlled EMC environments, the urban outdoors, heavy industrial environments or close to
railways, transmitters, overhead power lines etc. the performance of the unit may be degraded.
The product conforms to the following European electrical safety standard.
BS EN 60065:1998
Safety Considerations and Information
The unit must be earthed. Ensure that the mains power supply provides an effective earth
connection using a three-wire termination.
When the mains switch is in the off position the live and neutral conductors of the mains
transformer are disconnected.
CAUTION – Installation
Do not expose the unit to water or moisture
Do not expose the unit to naked flames.
Do not block or restrict any air vent
Do not operate the unit in ambient temperatures above 35
o
C
CAUTION - Mains Fuse
Replace the mains fuse only with the same type and rating as marked on the rear panel. The
fuse body size is 20mm x 5mm.
CAUTION – Servicing
The unit contains no user serviceable parts. Refer servicing to qualified service personnel. Do
not perform servicing unless you are qualified to do so.
Disconnect the power cable from the unit before removing the top panel and do not make any
internal adjustments with the unit switched on.
Only reassemble the unit using bolts/screws identical to the original parts
In the interest of continuing improvements Cloud Electronics Limited reserves the right to alter
specifications without prior notice.
Cloud Electronics Limited 140 Staniforth Road Sheffield S9 3HF England
Telephone +44 (0) 114 244 7051 Fax +44 (0) 114 242 5462 E-mail: [email protected]