Page 6: Local/remote, Remote, I.e., in its ‘in’ position. the front panel

background image

CDI-S100 Installation Guide v1.0

66























4. Screw the threaded ends of the two

25 mm mounting pillars supplied with the

CDI-S100 into the holes vacated by the
screws removed in Step 3.

5. On the CDI-S100 board, remove the two

small threaded bushes on the D-type

connector; retain them. An M3 nut-driver
is the best tool for this. Note that these

bushes also retain the metal connector

shell – be careful to keep it in place
during the next two steps.

UNSCREW THESE

TWO BUSHES

RETAIN METAL SHELL

REAR VIEW OF CDI-S100 PCB

6. Plug the connector on the end of the

ribbon cable into connector CON7 on
the CX462 main PCB. Note it can only be

inserted one way round, with the cable
exiting to the left.

7. With the CDI-S100 PCB upside-down,

insert the D-type connector through the
hole in the rear panel. You will see that the
two holes at the other end of the PCB are
aligned with the mounting pillars fitted in
Step 4. Fix the board to the pillars using
the screws removed in Step 3.

8. Replace the two bushes removed in Step

5 adjacent to the D-type connector by

screwing them through the rear panel.

CX462 jumper settings
In order for the CDI-S100 to fully control the

CX462, it is necessary to correctly set some
jumpers on the CX462 main PCB. These are J1

to J4, and J7 to J10.

MIC PREAMP

PCB

MIC ACCESS
CONNECTOR

REMOTE CONTROL

CONNECTORS

REAR EDGE

OF MAIN PCB

LINE 1

GAIN

CONTROL

J1 - J4

MUST BE

IN PLACE

J7 - J10 MUST ALL BE IN

THE ‘SW’ POSITION

J1 J2 J3 J4

LOCATION OF CX-462 JUMPERS

LOCATION OF CX-462 JUMPERS

Jumpers J1 to J4 are all on 2-pin headers, and

can thus be present or absent. They determine
how the CX462’s microphone access control

operates. When a CDI-S100 PCB is installed, all

four jumpers must be present.

Jumpers J7 to J10 determine how music

source selection and music level are controlled

remotely. When an CDI-S100 PCB is installed,

all four jumpers must be in the ‘SW’ position.

To move the jumpers, use small pliers to gently
pull the jumper off the header pins and replace

in the correct position. Do not use undue force,

and do not use pliers which are too big.

CX462 switch settings
After the CDI-S100 card has been fitted, and

J1 – J4 and J7 – J10 set as described above, the
top cover of the CX462 may be replaced, using
the original screws.

The blue rear panel switch

REMOTE TYPE

(adjacent to the REMOTE LINE SOURCE/

LEVEL CONTROL connector) should now be
set to

DIGITAL

– i.e., in its ‘in’ position.

The front panel

LOCAL/REMOTE

button

(adjacent to the mains switch) should be set to

REMOTE

(with the LED on).

The CX462 is now ready for serial remote
control.