18 technical specifications – Cloud Electronics CXA850 User Manual
Page 10
8
CX-A850: Installation and Operation Manual
08-03-05 V4
18
Technical Specifications
Number of Channels Driven
Rated Output 4 Ohm load(s)
Rated Output 8 Ohm load(s)
1
62W
36W
2
58W
34W
3
54W
32W
4
50W
30W
5
47W
29W
6
44W
28W
7
41W
27W
8
38W
26W
Bridged Output
100W nominal into 8 Ohm load, minimum load 8 Ohms
Frequency Response
+0dB –0.5dB 10Hz to 20kHz, switchable high pass filter –3dB
@65Hz
THD+N
0.007%, typical, @1kHz, 60W into 4 Ohms, one channel driven,
measurement BW 22Hz to 80kHz
VCA Module THD+N
<0.03% 1kHz, measurement BW 22Hz to 80kHz
-85dB (relative to 60W) @1kHz with 4 Ohm load
-82dB (relative to 60W) @10kHz with 4 Ohm load
-90dB (relative to 30W) @1kHz with 8 Ohm load
Crosstalk
Typical, between adjacent
channels
-90dB (relative to 30W) @10kHz with 8 Ohm load
Input Sensitivity
0dBu (775mV)
Input Impedance
10k balanced / 5k unbalanced
Noise
<96dB rms below rated output, unweighted, measurement BW
22Hz to 22kHz
Power Input
230V ±5% (115V ±5% available)
Fuse rating
230V – T4A H 115V – T8A H
Fuse type
20mm x 5mm class 3T 250V
This product conforms to the following European EMC Standards:
BS EN 55103-1:1997
BS EN 55103-2:1997
This product has been tested for use in commercial and light industrial environments. If the equipment
is used in controlled EMC environments, the urban outdoors, heavy industrial environments or close to
railways, transmitters, overhead power lines etc. the performance of the unit may be degraded.
The product conforms to the following European electrical safety standard.
BS EN 60065:1998