CX335 User Manual v1.0

9

cable can be used when connecting to an unbalanced
destination. Wire the inputs to the source devices using the
convention shown below:

1

2

3

CX335 output

pin 1: ground
pin 2: hot
pin 3: cold

Balanced amplifier input

+

-

pin 1: ground

pin 3: cold

pin 2: hot

Unbalanced amplifier input

(e.g., phonos)

screen: ground
pin: hot

BALANCED CONNECTION

UNBALANCED CONNECTION

1

2

3

1

2

3

CX335 output

pin 1: ground

pin 2: hot
pin 3: cold

External VCA Interface

The External VCA Interface is a 9-pin female Dsub
connector. The pinout is as follows:

PIN

FUNCTION

1

-15 V DC

2

0 V

3

VCA CONTROL IN

4

0 V

5

+15 V DC

6

0 V

7

8

9

1

2

3

4

5

9

8

7

6

+15

VCA IN

0V

-15

CX335 REMOTE LEVEL PINOUT

Connection for remote muting
The External VCA Interface may be wired to external N/O
(normally-open) relay contacts to mute the programme
audio in both channels when the contacts close. This is a

useful feature where it is necessary to mute music in an

emergency situation; in this case, the relay would probably
be part of the building’s fire alarm system.
Use two-core screened cable to connect to the remote
relay as shown:

1

9

8

7

6

5

4

3

2

N/O RELAY

CONTACTS

Note that to achieve maximum attenuation, the relay
contacts should be wired directly to pins 3 and 5 of the

Dsub connecter. In this case, the music level will be reduced
by approx. 60 dB when the external relay closes. Inserting a
resistor in series with pin 5 will reduce the amount by which

the music level drops on relay closure; it may be useful to
“dim” the music level in this way if the audio system includes
a paging facility where the paging signal is routed to the
amplifiers directly (i.e., does not route via the CX335).

RESISTOR VALUE

LEVEL CHANGE

0 ohms (i.e., no resistor)

-60 dB

470 kohms

-20 dB

1 Mohm

-12 dB

Connection for remote volume control
Another application for the External VCA interface is to
connect it to a rotary control (a variable resistor) to allow
the overall audio volume to be adjusted remotely. To achieve
this, wire the connector, using two-core screened cable, as
shown below:











Chassis Ground Terminal

The rear panel of the CX335 is fitted with an Earthing
(Grounding) Terminal [18]. This is provided for protection
purposes; grounding the CX335 is a safety measure to
protect the users of the system. The terminal should be
connected to a convenient earth point in the rack’s mains
distribution system.