beautypg.com

Cloud Electronics 46-120 - CDI-46 User Manual

Page 25

background image

CDI-46 Installation and Setup Guide V1.0

25

3.

Enable/Disable Mics
Either of the 46-120’s two mic inputs may be enabled or disabled. This may be done globally (for all zones), on a per-zone
basis. The value of x in the general format is the Mic input (1 or 2).

EXAMPLE

COMMAND (ASCII)

COMMAND (HEX)

Enable Mic 1 globally

3C 4D 31 2C 4F 2F 3E

Disable Mic 2 globally

3C 4D 32 2C 4D 2F 3E

Enable Mic 1 for Zone 2 only

3C 5A 32 2E 4D 31 2C 4F 2F 3E

4.

Enable/Release Paging

RS-232 control of paging allows an audio signal connected at

MIC 1 to be routed for paging.

This command differs from the others in that the value of y in the general format is in the form of a 4-character mask of ASCII
“X’s” (select) and “O’s” (don’t select), with the character position in the mask denoting the Zone number.

EXAMPLE

COMMAND (ASCII)

COMMAND (HEX)

Enable paging to Zone 3

3C 50 4D 2C 50 41 4F 4F 58 (4F) 2F 3E

Enable paging to Zones 1 and 4

3C 50 4D 2C 50 41 4F 4F 4F 58 2F 3E

Cancel paging

3C 50 4D 2C 50 52 2F 3E

Note that it is not strictly necessary to transmit the “O” character (4Fh) for channel numbers above the highest being paged.
Thus

(ASCII) would suffice in the first example above. However, the full four characters are shown in the table

for completeness, with the extra characters in brackets in the hex version.