Before You Call for Service

Problem Solution Guide

PROBLEM

MAY BE CAUSED BY

WHAT TO DO

nothing works.

raised vent not connected to elec-

trical power.

make sure power plug is connected to electri-

cal outlet.

power to vent’s electrical outlet is

off.

turn on power at circuit breaker or fuse box.

check for tripped breaker or blown fuse.

power outage.

contact power company.

Keypad is deactivated.

reactivate control panel: press high and low

keys at the same time. hold down for one

second.

vent intake raises or lowers

partially then stops.

an obstruction is interfering with

the vent intake movement.

immediately press up/Down key, then discon-

nect the power plug. remove the obstruction.

reconnect the vent power plug and press up/

Down key to raise or lower intake.

Gas flame is being pulled by

draw of vent.

short duct run or high output of

system make ventilating force very

strong.

reduce blower speed to a lower setting.

Clean filter symbol is lit.

blower has operated for over 40

hours.

Inspect and clean filters. See Care and Clean-

ing section.

Care and Cleaning

Cleaning the Intake Panel

the intake panels accumulate grease over time and

should be cleaned whenever the filters are washed.

After removing the grill and filters, wipe all external

and internal aluminum surfaces with a sponge or cloth

moistened with a mild detergent. rinse off with water.

remove all moisture by wiping with a soft, dry polish-

ing cloth. always wipe in the direction of the grain. Do

not use any abrasive substances on the intake panels,

as this may permanently mar the finish.
Dry and reinstall all components prior to operating the

vent system.

Cleaning the Electronic Keypad

Do not use any abrasive materials to clean the keypad.

the keypad and surrounding the plastic bezel should

be gently wiped with a lightly dampened sponge or

cloth. any material that becomes lodged between the

buttons and the surrounding bezel may be removed

by carefully dabbing with a cotton swab or the edge of

a cloth. use the above method to prevent the buttons

from sticking.
after cleaning, immediately dry the keypad area with

a soft cloth.

Cleaning the Top Cap

clean the top cap only when the intake vent is in the low-

ered position.
The top cap and end caps may have painted finishes

(depending on the model) that will scratch or stain if

cleaned with abrasive materials or harsh chemicals.

gently wipe them with a sponge or soft cloth moist-

ened in a mild detergent solution whenever they

becomes soiled. avoid introduction of moisture into

the electronic keypad area.