Important Safety Instructions

before operating the raised vent, verify that pot

handles or other objects will not interfere with the

raising and lowering of the vent intake. to prevent

spillage and damage to the vent system, turn

cookware handles to the side so that they will not

be hit when the vent moves to the “up” position.
clean liquid spills immediately. if liquid enters the

vent intake, then turn off the blower, disconnect the

power supply and carefully wipe up all liquid. see

the Care and Cleaning section of this manual.
never operate the vent without the filters in place.

Do not operate the blower if a flame or flare-up

develops. in the event of a flame, immediately

turn off the blower. smother the flame or use an

appropriate class dry chemical or foam-type fire

extinguisher.

Do not set or rest any objects, including cookware,

on top of the vent top cap. Do not interfere with the

movement of the vent intake in any way.
if the vent intake becomes jammed while being

raised or lowered, immediately press the up/

Down switch once to stop the intake motion,

then disconnect the power supply. remove the

obstruction, then restore power and press the up/

Down switch to continue raising or lowering the

intake.
clean this appliance only as instructed in this

manual. use only the cleaners specified.
never leave a cooktop or range unattended during

use.

warning

warning

Operation

warning

if the vent intake becomes jammed while being raised

or lowered, immediately press the uP/DoWn key once

to stop the intake motion, then disconnect the power

cord. remove the obstruction, reconnect the power plug

and press the uP/DoWn key to continue raising or

lowering the intake.

important

the direction of travel of the vent intake cannot be

reversed while it is moving. the intake must complete a

full up or down cycle before changing directions.

to operate the rv raised vent system when the vent

intake is in its lowered position, press and release the

uP/DoWn key on the control panel. the intake will take

approximately ten seconds to reach its uppermost posi-

tion, where it will stop.
the blower will turn on automatically and run on the

high speed setting. adjust the blower speed by pressing

and releasing either the meDIum or loW keys. the fan

speed may be changed whenever desired, as long as the

vent intake is in the fully raised position. the blower will

not operate if the intake is in any other position.
turn off the blower in one of two ways: press and release

the oFF key or lower the vent by pressing and releasing

the uP/DoWn key.

Operating Your Raised Vent

Parts the of raised Vent - shown raised

appearance varies with model number

top cap

intake

grill

control panel

uP/DoWn

loW

oFF

meDIum

HIGH