Dacor IVS1 User Manual
Ivs1, ivs2, ivsr1, ivsr2, Planning guide, Integrated ventilation system
PLANNING
GUIDE
Web: http://www.Dacor.com
Corporate Phone: 800-793-0093
Specifications are subject to change without notice.
See installation instructions for additional details.
7.14
Integrated Ventilation System
IVS1, IVS2, IVSR1, IVSR2
21 1/4"
(540mm)
22 1/2"
(572mm)
6"
(152mm)
11 1/16"
(281mm)
12 1/4"
(311mm)
Electrical
Access
Holes
8" (203mm) round exhaust
with back draft damper
IVS1/IVSR1 oVERALL DImENSIoNS
33 1/4"
(845mm)
34 1/2"
(876mm)
6" (152mm)
11 1/16"
(281mm)
12 1/4"
(311mm)
Electrical
Access
Holes
8" (203mm) round exhausts
with back draft damper
IVS2/IVSR2 oVERALL DImENSIoNS
21" (533mm)
8" (203mm)
13" (305mm)
10" Round
2" (51mm)
8" Exhaust
CL
CL
IVS1/IVSR1 oVERALL DImENSIoNS
(Top View)
8" Exhaust
CL
CL
CL
CL
6 1/2"
(165mm)
6 1/2"
(165mm)
IVS2/IVSR2 oVERALL DImENSIoNS
(Top View)
ATD10 oVERALL DImENSIoNS
(For use with IVS2 and IVSR2)
NOTES:
1. An internal blower is included with model IVS1
and IVS2. Blower Ratings: 1200CFM for IVS2 and
600CFM for IVS1.
2. Remote blower is required for IVSR1/IVSR2
models.
3. The ATD10 is sold seperately.
1/1
Revised
08/04/08
Model No.
Dedicated Circuit
Required
Maximum
Duct Length
Total
Connected Load
Approximate
Shipping Weight
IVS1
120 Vac, 60 Hz,
15 Amp Min. grounded,
dedicated circuit
Maximum 60
Equivalent
Straight Feet
0.2 kW (2 Amp)
25 lbs.
IVSR1
0.2 kW (1.5 Amp)*
21 lbs.
IVS2
0.4 kW (3 Amp)
38 lbs.
IVSR2
0.2 kW (1.5 Amp)*
29 lbs.
*Does not include remote blower