Steam vacuum operating procedure, During use – Dimplex SV8000 User Manual
Page 6
Steam vacuum
operating procedure
1 Switch mode switch
fl to position II.
•
Mode 2 switches on the boiler heater
and enables the handle control (i.e.
steam, vacuum and detergent switches).
2 Remove the top cover of the collection
tank
‡ and pour clean cold water into
the tank up to the white mark (approx 1
litre).
3 Replace top cover on the collection
tank.
4 Fill the Cold water tank
¤ with clean
water.
5 Connect the Solution tank hose to the
chemical point
⁄ on top of the machine
if required.
•
Fill the Solution tank with the
recommended detergent as required.
6 Connect vacuum hose and steam hose
to the front of the machine.
•
Ensure both parts are locked in position.
•
To release the vacuum hose slide back
the red button.
•
To release the steam hose lift the steam
flap before pulling out the hose.
7 Plug in machine cord to socket.
8 Ensure steam mode II is selected on
mode switch
fl.
9 Switch on power switch
fi, "Heater On"
light will illuminate.
10 Allow approximately 10 minutes for the
boiler to heat the water.
11 When the "Steam Ready" LED
illuminates the operator can commence
steam cleaning.
12 The handle controls are active and the
operator can switch on and off the
steam, vacuum and detergent supply.
•
Depressing the large button under the
handle will release the steam. This
button can only be locked in the off
position - slide the red button across to
lock.
•
Pressing the left hand switch (with fan
symbol) located on the top of the handle
will activate the vacuum.
•
Pressing the right hand momentry
switch located on the top of the handle
will activate the detergent pump. Hold
the switch for as long as you need to
dispense the detergent. Releasing the
switch will stop the detergent supply.
Note: steam and detergent cannot be
used at the same time.
13 The steam output can be adjusted by
the Steam Control knob
‹ on the top of
the machine.
14 The vacuum power can be adjusted by
the Vacuum Control knob
› on the top
of the machine.
15 Choose and fit the required accessory to
the hose handle. Lock the accessory in
place by turning the accessory locking
clip.
During use
Cold Water Tank empty
1
Refill the cold water tank when the
"Cold Water Refill" LED is illuminated, a
buzzer sounds and steam no longer
comes out of the nozzle when the steam
switch on the handle is pressed.
2 Always empty the collection tank
each time the cold water tank is
refilled.
3 Pour cold water in to the collection tank
to fill up to the white mark.
4 The pumps and vacuum will not operate
if the cold water tank is empty.
5 Once the "Cold Water Refill" LED is
activated the boiler heater will remain on
for 30 minutes. If the cold water tank is
not refilled within 30 minutes and the
machine is left powered ON the boiler
heater will switch off.
Solution Tank empty
If the detergent does not come out of
the nozzle when the detergent switch on
the handle is pressed - refill the "Solution"
tank.
Collection Tank full
1 The collection tank must be
emptied each time the cold water
tank is refilled
2 The pitch of the motor noise changes
and there is no suction at the nozzle -
indicates the collection tank is full and
needs emptying.