AIR CONDITIONER OPERATIONS AND PERFORMANCE

Location:

• In cooling operation, the air conditioner will dry the room air, so please fix a pipe to drain all the water away in

the air conditioner.

• Please let the indoor unit away from the TV set and the radio more than one meter in order to avoid the picture and

noise interference.

• Powerful radio transmitters or any other devices radiating high frequency radio waves can cause the air conditio-

ner to malfunction. Please consult the dealer where you purchased the air conditioner before installing it.

• Don't fix the unit in the dangerous region with combustible gas and volatile matter.
• lf the air conditioner is operated in an atmosphere containing oils (machine oil), salt near a coastal area, sulfide gas

near a hot spring, etc, such substances may lead to failure of the air conditioner.

• lf wrong using, installation, maintenance cause the air conditioner to malfunction, please consult your dealer.

Be careful with noise or vibrations

• Please fix the unit in the stable place to avoid the noise or vibrations.
• The noise near the air outlet of the outdoor unit may enter the air exit.
• Locate the outdoor unit where noise emitted by it or hot air from its air outlet will cause no nuisance to your neighbors.

lf the air conditioner sounds abnormal during operation, contact the dealer where your purchased the air conditioner.

Air conditioner operating conditions

For proper performance, run the air conditioner under the following temperature conditions:

lf air conditioner is used outside of the above conditions, safety protection features may come into operation.

Cooling

operation

Heating

operation

Dry

operation

Outdoor temperature: de 18 a 43°C

Room temperature: 17 a 32°C

Room temperature: 17 a 32°C

Room temperature: 0 a 27°C

Outdoor temperature: -7 a 24°C

CAUTION

Room relative humidity less than 80%. lf the air conditioner operates in excess
of this figure, the surface of the air conditioner may attract condensation.

Outdoor temperature: de 11 a 43°C

INSTALLATIÓN