CONVERSION TO A DIFFERENT TYPE OF GAS
Before converting the appliance for operation with a different gas type, check which type
of gas it is currently set to operate with (adhesive label (Figure 1) on appliance).
For the correct nozzle diameter, refer to the relative table in this booklet.
- Conversion procedure
* Disconnect the electrical power supply to the appliance;
* Change the main oven nozzle:
1) Remove the burner cover plate (see REMOVAL OF THE BURNER COVER PLATE
page 42).
2) Remove the screw securing the oven burner and withdraw the burner from the support
together with the heat sensor and the ignition spark plug. (Figure 5)
3) Remove the nozzle using a 7 mm box wrench (Figure 6)
4) Screw the new nozzle in fully (diameter in hundredths of millimetre stamped on the
nozzle), taking care not to cross the thread.
5) Replace the burner reversing the operations in step 2 above.
6) Replace the cover plate.
Fig. 5
Fig. 6
NOZZLE TABLE
The diameters in hundredths of millimetre are stamped on the nozzle.
Burner
Oven burner
Grill burner
kW
rated load
2,50
2,20
Ø Nozzle bore in
mm
G20
G30
G30
20 mbar
50 mbar
29 mbar
1,13
0,67
0,76
1,12
0,65
0,75