MAINTENANCE

An accurate maintenance guarantees good

functioning and long-lasting performance.

A special care is due to the grease filter.

VIE550BK grease filters replacement

Remove the lower cylindrical plate as shown

in Fig. 7, by pulling it downwards since it is

magnetically hold.

Remove the grease filters by acting on their

handle.

After 30 hours of operation of the cooker-

hood, the remote control will signal the filter

saturation by the simultaneous lighting of led

indicators; to reset, select the timer function

when the cooker-hood is off .

The metal grease filter can be washed by

hand or in the dishwasher.

The grease filter needs regular cleaning de-

pending on its use, once every two months

at least.

The charcoal filter needs to be replaced de-

pending on its use, once every six months at

least.

We recommend to use tepid water and a neu-

tral detergent to clean the appliance, while

abrasive products should be avoided .

The power cord replacement must be car-

ried out by specialized personnel only.

LED VIE550BK lamps replacement:

Remove the cooker-hood upper cover by re-

moving the 4 fixing screws , find the dama-

ged LED lamp and replace it with a new one

with the same characteristics.

Refit the upper cover.