Troubleshooting electrical connections – Caple CGi910 User Manual

Page 6

background image

6

If, having followed these instructions carefully, your cooker hood fails to work properly please carry out the following

checks.

Symptom CHECK

The cooker hood will not start

ƒ Check the hood is connected to the electricity supply.
ƒ Check that the fan speed control is set to 1, 2 or 3.

The cooker hood is not working

effectively

ƒ The fan speed is set high enough for the task.
ƒ The grease filter is clean.
ƒ The kitchen is adequately vented to allow the entry of fresh air.
ƒ If set up for recirculation, check that the charcoal filter is still

effective.

ƒ If set up for extraction, check that the ducting and outlets are

not blocked.

The cooker hood has switched off

during operation.

ƒ The safety cut-out device has been tripped.
ƒ Turn off the hob and then wait for the device to reset.


• If after all these checks, the problem persists, telephone the

Caple Service Centre 0844 800 3830

,

quoting the model and serial number.

• Please note that it will be necessary to provide proof of purchase for any in-guarantee service calls.
In-guarantee customers should ensure that the above checks have been made as the engineer

will make a charge if the fault is not a mechanical or electrical breakdown.

Electrical Requirements
ƒ Any permanent electrical installation must comply with the latest I.E.E. Regulations. For your own safety this should

be undertaken by a suitably qualified electrician who is on the roll of the National Inspection Council for Electrical

Installation Contracting (NICEIC).

ƒ THIS PRODUCT MUST BE CORRECTLY EARTHED. The connection must be made as follows: -

o

Brown

=

Live

o

Blue

=

neutral

o

Yellow/Green =

Earth

Electrical Connection
ƒ Before connecting to the mains supply ensure that the mains voltage corresponds to the voltage on the rating plate

inside the cooker hood.

ƒ This appliance is fitted with a 13 amp plug for connection to a suitable outlet which should be positioned for easy

access.

ƒ If it is intended to connect directly to the electricity supply, the plug should be removed and the 3 core mains cable

and should be permanently connected to the electricity supply via an approved Switched Fused Spur outlet meeting

BS1363 Part 4, fitted with a 3 Amp fuse.

ƒ This appliance conforms to BS 800: 1988 and EEC Directive No. 78 308 regarding suppression of radio and television

interference.

TROUBLESHOOTING

ELECTRICAL CONNECTIONS