Campomatic C960 User Manual
Page 7

GAS CONNECTION
At the oven edge of inner sides you will find a rating plate specifying the gas used for
calibration.
If you are using exactly the same type of gas, carefully follow the connection instructions.
If not, the oven must be adapted to the type of gas available before following connection
instructions.
Connection instructions
The appliance must be connected to the gas supply by means of a rigid metal pipe or a
metal hose in compliance with the regulations in force in the country.
The connection between the gas ramp coupling and the pipe must be made as follows:
1. tapered fitting (ISOR7) with seal on thread plus addition of suitable sealing agent;
2. by fitting an approved sealing gasket (aluminium, copper, rubber) in-between.
Warning: application of a rubber hose to the hose fitting is not allowed because it cannot
be inspected.
Caution: once you have finished the operation, check that there are no gas leaks by
testing with soapy water or equivalent. Do not use flames to test for gas leaks.
RAMP
GASKET
HOSE