Con-o operating instructions cont’d, Vacuum support kit – BUG-O Systems CON-O User Manual
Page 6

6
CON-O OPERATING INSTRUCTIONS CONT’D.
The illustration shows you that the
CON-O machine should be placed on the
work with the
Center Pin (R) located in the center-punch mark and two sets
of
Alignment Bars (W) straddling, equidistant, the longitudinal center-line.
The
Outrigger Support Kits (Q) should be arranged with the Magnet Foot
Assemblies (O) and Legs (M) approximately perpendicular to the work
surface if possible. Clamp securely to level and stabilize the
CON-O. The
Legs (U) are also symmetrically located so they will align the machine on
the layout line.
The
Four Straight Legs (U) are symmetrically located so that they too may
be used in aligning the machine. The type and size of work being done will
determine which methods of attachment are most advantageous.
LAYOUT AND SETUP
The only layout necessary is a centerline longitudinally [parallel to the axis
of the workpiece], a single
center-punch mark, and a second punch mark
[along the longitudinal centerline a distance from the center-punch mark equal
to the radius [on the
outside of the workpiece of the hole to be cut. If a bevel
hole is to be cut, layout a
third punch mark [along the longitudinal centerline]
a distance from the center-punch mark equal to the radius [on the
inside of
the workpiece] of the bevel hole to be cut.
TORCH
RACK
R
W
T
RIDING
WHEEL
W
INSIDE
SURFACE
OUTSIDE
RADIUS POINT
INSIDE
RADIUS POINT
LONGITUDINAL
CENTER LINE
CENTER
PUNCH MARK
OUTSIDE
SURFACE
SMALL DIAMETER
LARGE DIAMETER
15
ITEM PART NO. DESCRIPTION
1 CON-1020 Double Swivel Clamp Assembly
2 CON-1007 Vacuum Leg
3 ARV-1004-14 Hose 14" (355 mm)
4 ARV-1107 3/8" Hose Barb 1/4 NPT
5 ARV-1034 Choke Nipple
6 ARV-1109 Protective Cap
7 ARV-1116 Vacuum Cup (Silicone) 50 lbs. (22 kg)
8 ARV-1013 Male Quick Connector 1/4 NPY
* 9 ARV-2020 Vacuum Pump Kit (120 VAC/60 Hz/1Ph)
ARV-2030 Vacuum Pump Kit (220 VAC/60 Hz/1Ph)
10 ARV-1005 Hose Clamp
*Vacuum pump is not included in CON-1006 Vacuum Support Kit.
CON-1006 VACUUM SUPPORT KIT can be mounted on any CIR-O or CON-O
ring bases with standard CON-1003 legs. Vacuum pump kits are available for
operation on 120 VAC (ARV-2020) or 240 VAC (ARV-2030).
Each vacuum cup holds 50 lbs. (22 kg).
(Dirt and scale block vacuum lines; blowout when clogged).
Keep flame 4" (100 mm) away from cups when burning or welding. Silicone
vacuum cups will withstand a temperature of 600
0
F (318
0
C).
VACUUM SUPPORT KIT
1 3
2
10
4
6
7
5
8
9