beautypg.com

Con-o operating instructions cont’d, Vacuum support kit – BUG-O Systems CON-O User Manual

Page 6

background image

6

CON-O OPERATING INSTRUCTIONS CONT’D.

The illustration shows you that the

CON-O machine should be placed on the

work with the

Center Pin (R) located in the center-punch mark and two sets

of

Alignment Bars (W) straddling, equidistant, the longitudinal center-line.

The

Outrigger Support Kits (Q) should be arranged with the Magnet Foot

Assemblies (O) and Legs (M) approximately perpendicular to the work

surface if possible. Clamp securely to level and stabilize the

CON-O. The

Legs (U) are also symmetrically located so they will align the machine on

the layout line.

The

Four Straight Legs (U) are symmetrically located so that they too may

be used in aligning the machine. The type and size of work being done will

determine which methods of attachment are most advantageous.

LAYOUT AND SETUP

The only layout necessary is a centerline longitudinally [parallel to the axis

of the workpiece], a single

center-punch mark, and a second punch mark

[along the longitudinal centerline a distance from the center-punch mark equal

to the radius [on the

outside of the workpiece of the hole to be cut. If a bevel

hole is to be cut, layout a

third punch mark [along the longitudinal centerline]

a distance from the center-punch mark equal to the radius [on the

inside of

the workpiece] of the bevel hole to be cut.

TORCH

RACK

R

W

T

RIDING

WHEEL

W

INSIDE

SURFACE

OUTSIDE

RADIUS POINT

INSIDE

RADIUS POINT

LONGITUDINAL

CENTER LINE

CENTER

PUNCH MARK

OUTSIDE

SURFACE

SMALL DIAMETER

LARGE DIAMETER

15

ITEM PART NO. DESCRIPTION

1 CON-1020 Double Swivel Clamp Assembly

2 CON-1007 Vacuum Leg

3 ARV-1004-14 Hose 14" (355 mm)

4 ARV-1107 3/8" Hose Barb 1/4 NPT

5 ARV-1034 Choke Nipple

6 ARV-1109 Protective Cap

7 ARV-1116 Vacuum Cup (Silicone) 50 lbs. (22 kg)

8 ARV-1013 Male Quick Connector 1/4 NPY

* 9 ARV-2020 Vacuum Pump Kit (120 VAC/60 Hz/1Ph)

ARV-2030 Vacuum Pump Kit (220 VAC/60 Hz/1Ph)

10 ARV-1005 Hose Clamp

*Vacuum pump is not included in CON-1006 Vacuum Support Kit.

CON-1006 VACUUM SUPPORT KIT can be mounted on any CIR-O or CON-O

ring bases with standard CON-1003 legs. Vacuum pump kits are available for

operation on 120 VAC (ARV-2020) or 240 VAC (ARV-2030).

Each vacuum cup holds 50 lbs. (22 kg).

(Dirt and scale block vacuum lines; blowout when clogged).

Keep flame 4" (100 mm) away from cups when burning or welding. Silicone

vacuum cups will withstand a temperature of 600

0

F (318

0

C).

VACUUM SUPPORT KIT

1 3

2

10

4

6
7

5

8

9