SETUP CONT’d
Welder, Wire-feeder, Welding Gun, Weld and automatic Height Control Setup
CaS-2051-10 MdS aHC 10' (3.0 m) Remote Control
MAKE SURE THE WELDING POWER SOURCE is a Constant Voltage (CV) model and that it
is in the
CV MODE!!! If your welding power source is not or does not have a Constant Voltage
option the Automatic Height Control WILL NOT WORK!
To set your aUTOMaTIC HEIGHT CONTROL:
(Reference CAS-2051-10 MDS AHC 10' (3.0 m) Remote Control)
● Verify that the connection of the CAS-1550 Hall Effect Sensor Box is in-line within the welding
current circuit
● Set the height control
(Manual – automatic Toggle Switch) to manual mode.
● Set the torch height manually to the correct distance from the work piece using the
Up – down
JOG Toggle Switch
● Make a small weld and record the current reading from the power source.
● Now, dial the current reading into the Height Control
(amp dial).
● Turn the height control
(Manual – automatic Toggle Switch) to “Automatic”.
● The system should run at the same height and thus current.
NOTE: Some minor adjustment of the Amp Dial may be required to achieve the current output desired.
If the above does not work, it is possible that the slide on the Height Control is positioned in reverse.
If this happens;
● Physically turn the slide over, or reverse the motor leads.
● Then repeat the “running procedure” above again.
─ If it works now, check that the
Up – down JOG Toggle Switch works in the proper
direction. If not, it can be fixed by rotating the switch in the panel 180 degrees.
If this does not work consult the “Troubleshooting Page” in the back of this manual.
Up – Down JOG
Toggle Switch
Amp Dial
Manual – Automatic
Toggle Switch