GLOBAL PARAMETERS
A menu of Global Parameters is maintained in the K-BUG 1200. The menu consists of six (6) items as
described in Table 1, below. Access to the menu is locked when DIP Switch #1 is in the OFF Position.
Table 1: Global Parameters
Display Description
Default
Range
Units
n.0*
Travel Speed Coefficient
20.0
0.1 - 50
n.1
Motor Overload Stop Time
2
0.0 - 9.9
sec
n.2*
Travel Motor Reduce Ratio
80
20 - 200
base fig x 10 : 1
n.3*
Diameter of Travel Wheel
50
0.0 - 99.9
mm
n.4
Show Mode
off
off / on
n.5
Operating Units
U2
U1 / U2
U1 (cm/min), U2 (in/min)
* Indicates parameters NOT to be changed by the User. Changing these parameters can harm machine
performance.
ACCESS THE GLOBAL PARAMETER MENU
1. With machine unplugged from A/C power supply, remove the six (6) screws securing the Control
Interface (Legend Plate and Main PCB) to the Control Panel.
2. Remove the Control Interface and turn it over.
3. Locate DIP Switch 1 and 2 on the Main PCB, see
illustration at right.
4. Turn DIP Switch 1 to the “ON” position.
5. Turn over Control Interface. And secure to Control panel.
6. Plug in machine to A/C power supply of appropriate
voltage.
7. “0” should be shown in the Display.
8. Press and release Cycle Start button to cycle through
the six parameters (0, 1, 2, 3, 4, 5).
9. Use the Travel Speed Adjustment knob to change the
parameter setting.
10. When finished, unplug machine, remove Control
Interface and turn it over.
11. Turn DIP switch 1 to the “OFF” position to lock global
parameter menu.
12. Re-assemble Control Panel and plug in machine to begin operation.
CONVERTING UNITS
By default, the K-BUG 1200 will be factory set to operate in English units (in/min) and the K-BUG
1202 will be set to operate in Metric units (cm/min). If it is necessary to change units, follow the steps
to access the Global Parameters Menu, above. Use the Cycle Start button until “5” is shown on the
Display. Turn the Travel Speed Adjustment knob right or left to select the desired Units. Choose “U1” for
Metric (cm/min) or “U2” for English (in/min).