GLOBAL PARAMETERS

A menu of Global Parameters is maintained in the K-BUG 1200. The menu consists of six (6) items as

described in Table 1, below. Access to the menu is locked when DIP Switch #1 is in the OFF Position.

Table 1: Global Parameters

Display Description

Default

Range

Units

n.0*

Travel Speed Coefficient

20.0

0.1 - 50

n.1

Motor Overload Stop Time

2

0.0 - 9.9

sec

n.2*

Travel Motor Reduce Ratio

80

20 - 200

base fig x 10 : 1

n.3*

Diameter of Travel Wheel

50

0.0 - 99.9

mm

n.4

Show Mode

off

off / on

n.5

Operating Units

U2

U1 / U2

U1 (cm/min), U2 (in/min)

* Indicates parameters NOT to be changed by the User. Changing these parameters can harm machine

performance.

ACCESS THE GLOBAL PARAMETER MENU

1. With machine unplugged from A/C power supply, remove the six (6) screws securing the Control

Interface (Legend Plate and Main PCB) to the Control Panel.

2. Remove the Control Interface and turn it over.
3. Locate DIP Switch 1 and 2 on the Main PCB, see

illustration at right.

4. Turn DIP Switch 1 to the “ON” position.
5. Turn over Control Interface. And secure to Control panel.
6. Plug in machine to A/C power supply of appropriate

voltage.

7. “0” should be shown in the Display.
8. Press and release Cycle Start button to cycle through

the six parameters (0, 1, 2, 3, 4, 5).

9. Use the Travel Speed Adjustment knob to change the

parameter setting.

10. When finished, unplug machine, remove Control

Interface and turn it over.

11. Turn DIP switch 1 to the “OFF” position to lock global

parameter menu.

12. Re-assemble Control Panel and plug in machine to begin operation.

CONVERTING UNITS

By default, the K-BUG 1200 will be factory set to operate in English units (in/min) and the K-BUG

1202 will be set to operate in Metric units (cm/min). If it is necessary to change units, follow the steps

to access the Global Parameters Menu, above. Use the Cycle Start button until “5” is shown on the

Display. Turn the Travel Speed Adjustment knob right or left to select the desired Units. Choose “U1” for

Metric (cm/min) or “U2” for English (in/min).

Rear of Main PCB. Note DIP switch

placement on left hand side. Move

Switch 1 up to the ON position.