beautypg.com

Broadata Communications 285E Series User Manual

Page 11

background image

BCI 285E User’s Manual
Digital Fiber Optic Audio/Data Transport System

Broadata Technical Support, (800) 214-0222

12

RS-422 differential serial data
The 285E transmits and receives differential data signals com-
patible with Full Duplex RS-422 electrical signals (see
Figure 2-5). Note that the RS-422 does not support hand-
shaking control signals.
Use the following steps for data trans-
mission.

1.

For the near-end, label and connect one serial computer
data cable to the user’s RS-422 device.

2.

Connect the other end of this cable to the front panel RS-422
terminal block connector on the 285E.

3.

At the far-end, label and connect one serial computer data
cable to the remote RS-422 device.

4.

Connect the other end of this cable to the front panel RS-422
terminal block connector on the far-end 285E unit.

Figure 2-6 shows pin connections between the 285E unit (as a
DTE unit) and the user’s RS-422 device (as a DCE unit).

OUT

IN

+

_

+

_

Figure 2-5

Connector pinout for the RS-422 Interface