beautypg.com

Broadata Communications Mini-DVI-AD Series User Manual

Page 10

background image

Mini-DVI-AD User’s Manual

Miniature Multimode Fiber Optic DVI Transmission System

Broadata Technical Support, [email protected]

11

RS-422 differential serial data
The Mini-DVI-AD transmits one (1) channel of differential data
signals compatible with Full Duplex RS-422 electrical signals.
Note that RS-422 option is factory set and is not a standard
configuration. The RS-422 does not support handshaking
control signals.
Use the following steps for RS-422
transmission.

1.

For the near-end, label and connect one data cable to the
user’s RS-422 device.

2.

Connect the other end of this cable to the front panel RS-422
terminal block connector on the Mini-DVI-AD (see Figure 2-5).

Figure 2-5

RS-422 Terminal block pinout

1

O

2

1

2

D

A

I

GND

+ _

+ _