SETUP MENU
 Source Key (Front
“Input” Button/ Remote Controller “Source” Button)
-Menu: Select the input signals to the input menu OSD. 
-Rotate: Press Button to rotate the input source. 
 Auto Source
-
When there is no input signal, Auto Source change.
Communication
 Type
-Select the Communication: RS-422 or Lan
 Baud Rate _ 422 Baud Rate
- 2400/4800/9600/19200/38400/57600/115200
 Serial Protocol_422/Lan Protocol
-Basic / TSL 5.0 / TSL 4.0 / RDU/ Extension
 ID (01~99)
- If control each Board, must set ID numbers of each Board
IP Config
 Load Network Settings
-
ETHERNET cable connected after “Enter”. (ID/IP
Address/Gateway/Subnet Load)
 DHCP
-DHCP on/off (Manual IP settings
– DHCP on)
* “Apply” enter all settings after. 
 
Screen Saver
 Blue Screen
- Enables screen saver functions to avoid panel burning.
 BG Gray
- Select gray level on besides display picture. (0~7)
 Power Save
- DPMS (Display Power Management Signaling) Power Save 
Mode. 
Fan Control
 Fan Control
- Internal Fan Controls driving option by temperature sensor Auto / force on / force off
 Active Temp
- Adjusts fan driving temperature by Celsius degree. It works only when the Fan Control setting is Auto.
 Hysteresis
- Adjusts fan driving hysteresis temperature by Celsius degree. (1~10
℃
)
 Shutdown
- For a monitor protection is above of 75
℃
, Power Off.
Sync Check Period
- Sync Check Period at when switching the input signal (10 ~ 300 ms)