Setup menu – Boland Communications BVB Series User Manual
Page 22

User Manual
22 of 26
SETUP MENU
Source Key (Front
“Input” Button/ Remote Controller “Source” Button)
-Menu: Select the input signals to the input menu OSD.
-Rotate: Press Button to rotate the input source.
Auto Source
-
When there is no input signal, Auto Source change.
Communication
Type
-Select the Communication: RS-422 or Lan
Baud Rate _ 422 Baud Rate
- 2400/4800/9600/19200/38400/57600/115200
Serial Protocol_422/Lan Protocol
-Basic / TSL 5.0 / TSL 4.0 / RDU/ Extension
ID (01~99)
- If control each Board, must set ID numbers of each Board
IP Config
Load Network Settings
-
ETHERNET cable connected after “Enter”. (ID/IP
Address/Gateway/Subnet Load)
DHCP
-DHCP on/off (Manual IP settings
– DHCP on)
* “Apply” enter all settings after.
Screen Saver
Blue Screen
- Enables screen saver functions to avoid panel burning.
BG Gray
- Select gray level on besides display picture. (0~7)
Power Save
- DPMS (Display Power Management Signaling) Power Save
Mode.
Fan Control
Fan Control
- Internal Fan Controls driving option by temperature sensor Auto / force on / force off
Active Temp
- Adjusts fan driving temperature by Celsius degree. It works only when the Fan Control setting is Auto.
Hysteresis
- Adjusts fan driving hysteresis temperature by Celsius degree. (1~10
℃
)
Shutdown
- For a monitor protection is above of 75
℃
, Power Off.
Sync Check Period
- Sync Check Period at when switching the input signal (10 ~ 300 ms)