MAINTENANCE-REPLACEMENT OF THE DIVERTING CARTRIDGE
Before proceeding with the maintenance of the cartridge, remove the regulation handle.
Follow the instructions shown in section “HANDLES REMOVAL” at pag.14
1) Unscrew the chromed adapter(1) anti-clockwise, paying attention not to lose the O-
ring(2)
2) Remove the cover plate.
3) Close the water inlets.
Remove the screw (3), remove the brass insert (4) and unscrew the threaded rod (5).
Unscrew the flange(6) anti-clockwise, with a 21 mm wrench.
Remove the diverting cartridge(7).
4) Before replacing the cartridge, clean thoroughly and grease the inner seat of the body.
5) Replace the cartridge. In case of
TWO WAY DIVERTER, place the two pivots in their
seats. With a
THREE WAY DIVERTER, place the single pivot in its seat.
6) Reassemble all parts.
5
page 14.
21mm (⅞”) wrench.