Below is an overview for the connection of the Indoor unit to the Outdoor unit.

OVERVIEW

This appliance must be installed according to national power supply acquirement.

Drain
Hose

Ground Wire
(Not Supplied)

Gas side piping
Oxygen tube

Connecting

cable

Liquid side piping

Drain Hose

Pipes

(Not Supplied)

Wall

Bracket

AC

Connection

(Not Supplied)

Wrap with

Tape

AC Outlet

and Plug

Copper
Tubing

10cm (3.95in)
from ceiling

At least 30cm

(11.8in) from unit

30cm (11.8in) from

side wall

10cm (3.95in) from

side wall

Maximum Height

7M (21Ft)

Maximum Length

15M (49Ft)

Any tube length between 7 and 15 meters must

be precharged with freon using the following calulation:

(Length — 5) x 30 grams

Adding additonal tubing will decrease efficiency

10

cm

70

cm

60

cm

3.9 inches

23.6
inches

60

cm

23.6
inches

27.6
inches

Plug into 220V~240V

AC Outlet

Gas side piping

Connecting

cable

Liquid side piping

Drain Hose

Cooling Only

* DSB-AH Series model has oxygen tube, but the other models do not.

Heating & Cooling

NOTES:

After installation it must be

possible for the user to dis -
connect the power supply
plug.

If the AC outlet is a 3-

pronged type or other, have
an electrician install a new
outlet.

Contanct service man when

replace the power cord set.

The specification of AC con -

nection is 2.0mm

2

x 3C x 6m.

INSTRUCTION OF INSTALLATION

Wall

Wall Cap

Oxygen tube

Drain
Hose

Oxygen tube

17