Worksheet for parameter measurement – Diversified Ceramics DISPLACEMENT FOLLOWER 5100 User Manual
Page 21

Displacement Follower User’s Manual
Version 1.4, April 19, 2004
IM1008
Page 19
Worksheet For Parameter Measurement
1. System Field of View = FOV = inches or millimeters
2. Accel. Due to gravity = 386.4 in. / sec
2
= 9814 mm / sec
2
3. Set Velocity Time for Velocity output less than 10V P-P
4. Set Accel. time for Accel. output less than 10V P-P
5. Vel Full Scale = FOV
= in / sec
Vel Time (seconds)
= mm / sec
6. Target Vel
= Vel Output (peak) X Vel Full Scale
5
7. Vel Output = Peak Vel Output = volts/ in / sec
Sensitivity
Target Vel
8. Accel Full Scale = Vel Full Scale = in / sec
2
,
Accel Time (seconds)
= mm / sec
2
9. Target Accel = Accel Output (peak) X Accel Full Scale = in / sec
2
= mm / sec
2
10. Target “g”
= Target Accel (in / sec
2
) English
386.4 in / sec
2
Target “g”
= Target Accel (in / sec
2
) Metric
9814 mm / sec
2
11. Accel Output = Peak Accel. Output = volts/ g
Sensitivity
Target Accel