Beurer LB 50 User Manual
Page 21

19
7
IN THE EVENT OF PROBLEMS
Problem
Cause
Remedy
No steam
exiting
Appliance not connected to power
Insert the plug [14] into the
mains and switch on the
appliance.
Water tank [8] empty.
Replenish water.
Water tank [8] not fitted correctly.
Fit tank properly.
Appliance
leaking
Water tank [8] leaking.
Replace tank.
Water tank [8] not shut properly.
Fasten the catch properly.
Steam tower [3] not installed or not
installed correctly.
Install steam tower [3]
properly.
Delay in steam
output
Very cold water in tank.
Use warmer water.
Appliance heavily scaled.
Descale the appliance.
Red indicator
[A] illuminated
Water tank [8] empty.
Replenish water.
Valve on tank catch [9] is covered
with dirt.
Clean the valve.
Appliance heavily scaled.
Descale the appliance.
Water tank [8] not shut properly.
Close the catch properly.
Water tank [8] not fitted correctly.
Fit tank properly.
If the problem persists, please contact customer service.
8 T
ECHNICAL DETAILS
Rated output
380 W
Nominal voltage
230 V / 50 Hz
Water tank volume
approx. 5 litres
Evaporation rate
• Level 1: 150 ml/h
• Level II: 400 ml/h
Overheating protection
Through thermostat
Safeguard against running dry
If there is not enough water in the heater unit, the
appliance switches off automatically. The appliance has
a sensor which detects the water level.
Switching 2-stage
Weight 2.8
kg
Dimensions (W / H / D)
235 / 315 / 280 mm
Connection
Fixed cable, approx. 2 m in length