3.
Remove inner bag filter (J) Fig. 19, in the same
manner.
Fig. 19
J
4.
The first stage filter (H) Fig. 18, can be replaced or
cleaned depending on its condition. This filter can be
cleaned in one of two methods: a shop-vac can be used
to remove the dust, or compressed air can be used to
blow the dust out of the filter.
W A R N I N G : C O M P R E S S E D A I R C A N B E
DANGEROUS. FOR OPERATOR SAFETY, DO NOT
EXCEED AN AIR PRESSURE OF 30 PSI OR POINT AIR
NOZZLE TOWARD ANYONE OR AIM AIR NOZZLE AT
YOUR OWN BODY. ALWAYS WEAR SAFETY GLASSES
A N D D U S T M A S K W H E N P E R F O R M I N G T H I S
PROCEDURE.
5.
The inner bag filter (J) Fig. 19, cannot be cleaned; it
is disposable and must be replaced.
6.
Install both filters in the reverse order in which they
were removed. NOTE: Make certain the AIR FLOW
ARROW on each filter is pointing inward toward the
rear of the air cleaner, as illustrated in Fig. 19.