Technical data – BECKHOFF M1410 User Manual
Page 6

M1410 Parallel Input / Output
Beckhoff II/O-System
Page 6 von 14
Version : 2.0
Date : 2.8.94
3. Technical Data
Inputs / Outputs
16, can be configured for each port;
LED shows
state of all inputs / outputs
Input Specifications
24 VDC, 10 mA, digital filter
input switching voltages
0 - 8V = LOW
15 - 24V = HIGH
input delay
0,7 ms RC network
6,8 ms input latch
Output Specifications
24 VDC, max. 500 mA, short circuit proof
Output check
watchdog system 100ms
Connections
can be connected for 16 I/O; +,-,signal
Data Connection
fibre optic II/O system
Transmission Rate
2,5 MBaud, 25 µs for 32 Bit
Supply Voltage
24 VDC (± 10%)
Input Current
0,1 A (without load and input currents)
Cartridge
closed, can be installed to cartridge carrier
according to DIN EN 50022, 50035
Size (B * W * D)
170 * 76 * 68 mm
Weight
about 700 g
Working Temperature
±0..+55 øC
Storage Temperature
-20..+70 øC