10 technical data, Drive technology – BECKHOFF AM3100 User Manual
Page 24
9 Commissioning
Drive Technology
24 Version:
1.4
AM3100
Fault
Possible cause
Measures to remove the cause
of the fault
Motor doesn’t rotate
•
Servo terminal not enabled
•
Break in setpoint lead
•
Motor phases in wrong
sequence
•
Brake not released
•
Drive is mechanically blocked
•
Supply ENABLE signal
•
Check setpoint lead
•
Correct the phase sequence
•
Check brake control
•
Check mechanism
Motor runs away
•
Motor phases in wrong
sequence
•
Correct the phase sequence
Motor oscillates
•
Break in the shielding of the
feedback cable
•
Amplification to high
•
Replace feedback cable
•
Use motor default values
Error message: brake
•
Short-circuit in the supply
voltage lead to the motor
holding brake
•
Faulty motor holding brake
•
Remove the short circuit
•
Replace motor
Error message: output stage
fault
•
Motor cable has short circuit or
earth leakage
•
Motor has short circuit or earth
leakage
•
Replace motor cable
•
Replace motor
Error message: feedback
•
Connector is not properly
plugged in
•
Break in cable, cable crushed
or similar
•
Check connector
•
Check cables
Brake does not grip
•
Required holding torque too
high
•
Brake faulty
•
Check the dimensioning
•
Replace motor