Connection methods
l
Carry out the wiring in accordance with the valid standards and regulations.
l
Only use our preassembled shielded leads for the resolver and power connections.
l
Connect up the shielding according to the wiring diagrams in the Installation
Instructions for the servoamplifier.
l
Incorrectly installed shielding inevitably leads to EMC interference.
In the table below you find all leads supplied by us. Further information referring to chemi-
cal, mechanical and electrical qualities can be received from our applications department.
Insulating material
Sheathing
- PUR (Polyurethane, identification 11Y)
core insulation - PETP (Polyesteraphtalate, identification 12Y)
Capacity
Motor lead
- less than 150 pF/m
Resolver lead - less than 120 pF/m
Technical Data
—
All leads are suitable for trailing.
—
Technical data refer to mobile usage of leads.
Life time : 1 Million bending cycles
—
The temperature range refers to the operation temperature.
—
Identification:
N
= numbered cores
F
= cores with colour code according to DIN 47100
B
= cores with letter identification
( )
= shielding
Cores
[mm²]
Identification Temperature range
[°C]
Cable diameter
[mm]
Bending radius
[mm]
Remarks
(4x1,0)
F
-30 / +80
10,5
105
Motor lead
(4x1,5)
B
-30 / +80
11,3
115
(4x2,5)
N
-5 / +70
12,7
125
(4x1,0+(2x0,75))
F
-30 / +80
12
120
Motor lead with
integral brake
control leads
(4x1,5+(2x0,75))
B
-10 / +80
12,5
125
(4x2,5+(2x1))
B
-30 / +80
13,8
140
(4x2x0,25)
F
-30 / +80
6,9
60
Resolver lead
18
Motor series AM227..297
Installation / Commissioning
12/2001