Led 05 - not used, Led 06 - cp-link run, Led 07 - cp-link comm-err – BECKHOFF CP9030 User Manual

Page 26: Jumper assignments, Isa bus current consumption

background image

Technical Data CP9030

LED 05 - Not used

LED 06 - CP-Link RUN

This LED flashes for a short period when the computer is switched on, and
then becomes continuously lit. When the LED is lit, the communication
software on the CP-Link has started running.

LED 07 - CP-Link COMM-ERR

If the LED flashes, data errors are occurring. A single flash when the screen
mode is changed is normal. Transmission is then resynchronised. If the
LED continues flashing, then either the coaxial cable is damaged, or there is
excessive interference from other devices such as frequency converters,
large transformers, etc.. This may be remedied through the use of high-
quality double-screened coaxial cable.

Jumper Assignments

JU200

10 inch display in the Control Panel (OPEN)

JU203 (CP9030_3)

JU201
Floppy in the Control Panel (OPEN)

JU202
Floppy in the Control Panel (OPEN)

JU401
12V (always set)

JU402
12V (always set)

J300
If the jumper is set then it is possible for the Control Panel's keyboard to be
disabled under TwinCat.

J501
If this jumper and jumper J300 are set then it is possible for the Control
Panel's keyboard and touchscreen to be disabled under TwinCat.

The standard setting is for JU200 (JU203), JU201, JU202, JU401 and
JU402 to be set. Do not change any of the factory settings without first
contacting our Technical Support.

ISA bus current consumption

The CP9030 card is powered primarily from the PC's ISA bus. At larger
distances (> 50 m) it is recommended that the additional power supply
connection, ST404, is used.

ISA bus current consumption 5V:

approx. 1.0 A

ISA bus current consumption 12V:

approx. 1.5 A

CP9030 / CP9035

27