beautypg.com

BECKHOFF CP9030 User Manual

Page 19

background image

Technical Data CP9030


LED1..256

Output for LEDs; "1" = LED on
Up to 256 LEDs can be controlled

BUTTON1..256
Inputs for buttons; "1" = button pressed
Up to 256 buttons can be read

No. of pd outp. words (number of process data output words)
A reference value with which the output status derived from the Control
Panel (CP2020 pd outp.words) is compared. If they differ, then for reasons
of safety no outputs are set.

No. of pd inp. words (number of process data input words)
A reference value with which the input status derived from the Control Panel
(CP2020 pd inp.words) is compared. If they differ, then for reasons of
safety no outputs are set. Inputs can continue to be read.

Pd cycles (process data cycles)
A continuously incremented 8-bit counter. If it is active, Pd errors remains
unchanged.

Pd errors (process data errors)
An error counter that is incremented whenever errors occur in transmission
protocols.

CP2020 Pd outp. words (process data output words)
Returns the size (in words) of the process data output status determined by
the Control Panel.

CP2020 Pd inp. words (process data input words)
Returns the size (in words) of the process data input status determined by
the Control Panel.

CP-Control
Reset request : "1" reset of the CP-Link electronics

CP-state
Reset ackn.

: "1" - reset carried out

PDLenErr

: "1" process data length error

CnfErr

: "1"

KbusErr

: "1" - communication error; e.g. to the button extensions

C9900-E6xx

UPS control
Active

: "1" battery operation is supported

UPS Status
Ext. vers. OK : "1" input voltage (24V DC) is present
Battery voltage : "1" - the battery voltage is sufficient
Charging

: "1" - The battery pack is being charged

No battery

: "1" - The battery pack is not present or is defective

Charged

: "1" - The battery pack is fully charged

Waiting : "1" - Pause during the process of charging the battery pack

20

CP9030 / CP9035

This manual is related to the following products: