Interfaces, Power supply, Network connection – BECKHOFF C6920 User Manual
Page 12: Usb-interfaces, Dvi (digital visual interface), Serial interface, Fieldbus, Additional plug-in cards (optional), Interfaces 10, Usb-interfaces 10
Product Description
Interfaces
Interfaces to the
C6920/ 25 Industrial PCs
Power Supply
Power supply
The power supply for the Industrial PC is established via the
socket (X101).
Network connection
Network
10/100/1000BASE-T
The RJ-45 connector (X102) allows the PC to be connected to a
10/100/1000BASE-T Local Area Network (LAN).
Network
10/100/1000BASE-T
The RJ-45 connector (X103) allows the PC to be connected to a
10/100/1000BASE-T Local Area Network (LAN) (version -0020 and
higher).
Network 10/100BASE-T
The RJ-45 connector (X103) allows the PC to be connected to a
10/100BASE-T Local Area Network (LAN) (till version –0020).
USB-Interfaces
USB1 – USB4
The four USB interfaces (X104 – X107) are used for connecting peripheral
devices with USB connection. USB2.0 standard is supported.
DVI (Digital Visual Interface)
DVI-I
The DVI connection (X108) is used for transferring the video signal. DVI-I
standard is supported.
Serial interface
RS 232
COM1
The Industrial PC has one serial interfaces, COM1 (X109), using the type
RS232, which is brought to a 9 pin SUB-D plug connector.
Fieldbus
Fieldbus
The Industrial PC has one fieldbus-interface (X110), which is brought to a
9 pin SUB-D plug connector.
Additional plug-in cards (optional)
Type plate
There is a type plate on the top of the Industrial PC which provides
information about the hardware configuration of the Industrial PC at the
time it was supplied.
Ground connection
X104
X105
X106
X107
X101
X102
X103
X109
X108
X110
10