beautypg.com

Power supply connection, Mains socket, Power supply cords – BECKHOFF C5101 User Manual

Page 15

background image

Installation Instructions


Power Supply Connection

Supplied mains power unit The Industrial PC is fitted with a 100-240 V, 50-60 Hz full range power

supply unit (with the option of an uninterruptible power supply, UPS).


Current carrying capacity
of the 100-240 V power
supply unit

Output voltages from

the 100-240 V power

supply unit

Current loading
maximum

+3,3 V

16 A

+5 V stand by

2 A

+5 V

25 A

-5 V

0,3 A

+12 V

13 A

-12 V

0,8 A


Mains Socket

A mains socket is located at the rear of the PC housing in order to connect
the power supply.

Socket at the PC housing


Power supply cords

Power cords Europe

In the area Europe you use the provided cable with inlet connector for non-
heating apparatus to connect the Industrial-PC to the power supply.

Power cords USA / Canada In the area USA / Canada the power supply cable must show the following

specifications according to the supply voltage:
Listed, Detachable, maximum 4.5 m (14.76 ft.) long; rated minimum 125 V,
10 A, Type SJT or Type SVT; one end terminates in NEMA 5-15P/-20P
grounding-type attachment plug, other end in appliance coupler
or
Listed, Detachable, maximum 4.5 m (14.76 ft.) long; rated minimum 250 V,
10 A, Type SJT or Type SVT; one end terminates in NEMA 6-15P/-20P
grounding-type attachment plug, other end in appliance coupler.

C5101

13

This manual is related to the following products: