beautypg.com

Pin assignment and cable requirements, Industrial pcs with 100-240 vac, 50-60 hz power, Industrial pcs with 24 vdc power supply unit – BECKHOFF CP65xx User Manual

Page 16

background image

Installation Instructions


Coding pieces

The connectors are coded differently at the factory, using snap-on coding
pieces, according to the power supply unit that has been fitted.

Differently coded plug
connectors

Coding for the 100-240 V

AC

,

50-60 Hz power supply unit

Coding for the 24 V

DC

power supply

unit


Pin assignment and cable requirements

Pin assignment

There is an adhesive label with the pin assignments on the top of the
female plug connector. The minimum permitted conductive cross-
section is 1.5 mm², fused for 10 A (AWG 16).

Industrial PCs with 100-240 V

AC

, 50-60 Hz power supply unit


Pin assignment for the
100-240 V, 50-60 Hz power
supply unit


Pin

Function

1

N

2

L

100 – 240V

AC

Power supply

3

4

Not used

5

Not used

5 4

2

3

1


Industrial PCs with 24 V

DC

power supply unit


Pin assignment for the
24 V

DC

power supply unit


Pin

Function

1

+

2

-

24V

DC

Power supply

3

4

Not used

5

Not used

5 4

2

3

1

14

CP65xx

This manual is related to the following products: