beautypg.com

Baumatic BC392.2TCSS User Manual

Page 34

background image

34


o

Unscrew the injector and replace it with the
stipulated injector for the new gas supply
(see table below).








Gas

consumption

Power

(kW)

Burner Types

of gas

Pressure

(mbar)

Injector
Marking

(1/100

mm)

g/h l/h

Max.

Min.

Natural

(G20)

20

72 -

95

Butane

(G30)

30 50

73

-

Auxiliary

Propane

(G31)

37 50

71

-

1.00 0.48

Natural

(G20)

20 97 -

167

Butane

(G30)

30 65

127

-

Semi-
rapid

Propane

(G31)

37 65

125

-

1.75 0.60

Natural

(G20)

20 115 -

286

Butane

(G30)

30 85

254

-

Rapid

Propane

(G31)

37 85

250

-

3.00 1.05

Natural

(G20)

20 135 -

286

Butane

(G30)

30 95

218

-

Wok

Propane

(G31)

37 95

214

-

3.50 1.80


o

Reassemble all the burners carefully; in particular you should
make sure that the flame spreader is correctly placed on the
burner.


IMPORTANT: After changing the injectors YOU MUST follow the
minimum flow adjustment section on the next page.