beautypg.com

Clearing a jam from the tool – DeVillbiss Air Power Company 2by4 Contractor Series User Manual

Page 13

background image

PAGE 13

Disconnect tool from air compressor
before adjusting, clearing jams, servicing,
relocating and during non-operation.

FASTENER JAMMED IN FASTENER
DISCHARGE AREA:

1. Disconnect tool from air hose.

2. NF2502X4, NB1252X4, NB2002X4,

NBSNC2X4
Release the magazine latch to open the
magazine.

CLEARING A JAM FROM THE TOOL

Feeder

Magazine

Latch

Nose

Cover

Latch

SNC1002x4

Pull feeder shoe back into "locked" position.

3. Remove fasteners from magazine.

4. NF2502X4, SNC1002X4, NB2002X4, and

NB1252X4

Lift nose cover latch to unlatch and re-
move driver guide cover.

NBSNC2x4

Loosen the screws on the driver guide
cover and then remove the driver guide
cover.

5. Using pliers remove fasteners.

6. NF2502X4, NB1252X4, NB2002X4, and

SNC1002X4

Replace nose cover and latch into place.

NBSNC2X4

Replace nose cover.

7. Reload fasteners into magazine. Refer to

Loading the Tool section in this manual.